Specifications: Fluke 15B+ Digital Multimeter

Accuracy Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).

FunctionRangeResolutionAccuracy
AC volts(40 Hz to 500Hz)14.000 V40.00 V400.0 V1000 V0.001 V0.01 V0.1 V1 V1.0% + 3
DC volts4.000 V40.00 V400.0 V1000 V0.001 V0.01 V0.1 V1 V0.5% + 3
AC millivolts400.0 mV0.1 mV3.0% + 3
DC millivolts400.0 mV0.1 mV1.0% + 10
Diode test22.000 V0.001 V10%
Resistance(Ohms)400.0 Ω4.000 kΩ40.00 kΩ400.0 kΩ4.000 MΩ40.00 MΩ0.1 Ω0.001 kΩ0.01 kΩ0.1 kΩ0.001 MΩ0.01 MΩ0.5% + 30.5% + 20.5% + 20.5% + 20.5% + 21.5% + 3
Capacitance340.00 nF400.0 nF4.000 μF40.00 μF400.0 μF1000 μF0.01 nF0.1 nF0.001 μF0.01 μF0.1 μF1 μF2% + 52% + 55% + 55% + 55% + 55% + 5
AC current μA(40 Hz to 400 Hz)400.0 μA4000 μA0.1 μA1 μA1.5% + 3
AC current mA(40 Hz to 400 Hz)40.00 mA400.0 mA0.01 mA0.1 mA1.5% + 3
AC current A(40 Hz to 400 Hz)4.000 A10.00 A0.001 A0.01 A1.5% + 3
DC current μA400.0 μA4000 μA0.1 μA1 μA1.5% + 3
DC current mA40.00 mA400.0 mA0.01 mA0.1 mA1.5% + 3
DC current A4.000 A10.00 A0.001 A0.01 A1.5% + 3

BacklightYes

1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
FunctionOverload protectionInput impedance (Nominal)Common mode rejection ratioNormal mode rejection ratio
AC volts1000 V1>10 MΩ <100 pF>60 dB at dc,50 Hz or 60 Hz-
AC millivolts400 mV>1MΩ, <100 pF>80 dB at 50 Hz or 60 Hz-
DC volts1000 V1>10 MΩ <100 pF>100 dB at dc,50 Hz or 60 Hz>60 dB at 50 Hz or 60 Hz
DC millivolts400 mV>1MΩ, <100 pF>80 dB at 50 Hz or 60 Hz-

1106V Hz Max

General specifications
Maximum voltage between any terminal and earth ground1000 V
Display (LCD)4000 counts, updates 3/sec
Battery type2 AA, NEDA 15A, IEC LR6
Battery life500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)

Temperature
Operating0 °C to 40 °C
Storage-30 °C to 60 °C

Relative humidity
Operating humidityNon-condensing (<10°C)≤90% RH at 10 °C to 30 °C;≤75% RH at 30 °C to 40 °C

40 MΩ range≤80% RH at 10 °C to 30 °C;≤70% RH at 30 °C to 40 °C

Altitude
Operating2000 m
Storage12,000 m
Temperature coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs440 mA, 1000 V Fast Fuse, Fluke specified part only.11A, 1000V Fast Fuse, Fluke specified part only.
Size (H x W x L)183 x 91 x 49.5 mm
Weight455 g
IP ratingIP 40
SafetyIEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
Electromagnetic environmentIEC 61326-1: Portable
Electromagnetic compatibilityApplies to use in Korea only

Class A equipment (industrial broadcasting & communication equipment)11This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller oruser should take notice of it. This equipment is intended for use in business environments and is not to beused in homes.

Package Includes:

  • Fluke 15B+ Digital Multimeter
  • TL75 test leads with two caps
  • 2 AA batteries
  • User’s manual