Fluke 317 AC/DC Clamp Meters 600A


Tk 25000


Product overview: Fluke 317 Clamp Meters

The Fluke 317 and 319 are designed with ergonomic concepts, shaped to fit your hand and to access tight spots easily. These small and rugged clamp meters are ideally suited for current measurements up to 1000 A (319) in tight cable compartments. The Fluke 317and 319 also offer AC/DC current measurements and has a higher resolution for loads below 40 A. In addition to a compact package with a strong feature set, the Fluke 319 also equip with In-rush current and Frequency functions for testing motors, lighting, etc.

Product overview: Fluke 317 Clamp Meters

The Fluke 317 and 319 are designed with ergonomic concepts, shaped to fit your hand and to access tight spots easily. These small and rugged clamp meters are ideally suited for current measurements up to 1000 A (319) in tight cable compartments. The Fluke 317and 319 also offer AC/DC current measurements and has a higher resolution for loads below 40 A. In addition to a compact package with a strong feature set, the Fluke 319 also equip with In-rush current and Frequency functions for testing motors, lighting, etc.

317 Electrical specifications
Current ACRange40.00 A, 600.0 A

Resolution0.01 A, 0.1 A

Accuracy1.6% ±6 digit (50-60 Hz) {40 A}

2.5% ±8 digit (60-500 Hz) {40 A}

1.5% ±5 digit (50-60 Hz) {600 A}

2.5% ±5 digit (60-500 Hz) {600 A}

Crest Factor add 2% into spec for CF > 23.0 Max @ 500 A, 2.5 Max @ 600 A

AC responserms
Current DCRange40.00 A, 600.0 A

Resolution0.01 A, 0.1 A

Accuracy1.6% ±6 digit (40 A)

1.5% ±5 digit (600 A)
Voltage ACRange600.0 V

Resolution0.1 V

Accuracy1.5% ±5 digit (20-500Hz)

AC responserms
Voltage DCRange600.0 V

Resolution0.1 V

Accuracy1% ±4 digit
ResistanceRange400.0 Ω, 4000 Ω

Resolution0.1 Ω, 1 Ω

Accuracy1% ±5 digit

Continuity≤ 30 Ω
InrushIntegration timeN/A
FrequencyRangeN/A

AccuracyN/A

Trigger LevelN/A

Environmental specifications
Operating temperature14°F to 122°F (-10 °C to 50 °C)
Storage temperature-40 °F to 140 °F (-40 °C to 60 °C)
Operating humidityNon-condensing (< 50 °F) (< 10 °C)

90% RH (50 °F to 86 °F) (10 °C to 30 °C)

75% RH (86 °F to 104 °F) (30 °C to 40 °C)

45% RH (104 °F to 122 °F) (40 °C to 50 °C)

(Without condensation)
Operating altitude1 mile (2000 meters) above mean sea level
Storage altitude7 miles (12,000 meters) above mean sea level
IP RatingIP40
Vibration requirementsRandom MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis
Drop test requirements3 ft (1 m) drop test, six sides, oak floor
EMI, RFI, EMCInstrument unspecified for use in EMC field ≥ 0.1 V/m
Temperature coefficients0.1x (specified accuracy)/ °C

(<64 °F or > 82° F)

(<18 °C or > 28 °C)






Customer Questions and answers :